Cumhuriyetimizin 100. Yılı Kutlu Olsun
High-tech at every step

Santest GYSE-A-PF Series Profile Type Contactless Linear Scale

Santest GYSE-A-PF Probe

High performance analogue output (detachable probe element)

This is the linear profile version of GYSE-A. It is a high performance analog output probe, and has the high resolution of 16bit. It has also velocity output. Using two pcs of magnet on the probe as another option, detecting each magnet position or relative distance between the two is possible. The inside probe element can be detached from the outer housing, and with the captive software (GPM), zero and gain adjustment is possible at user side.

Specifications

ACCURACY
Non-linearity ≦±0.025%FS TYP
Resolution 16bit(1/65536)
Repeatability ≦±0.001%FS (Min. ±3μm)
Temp. drift ≦±20ppmFS/℃
OUTPUT
Position (STD) 0~10V(output current : Max.5mA, load : Min.2kΩ)
or 4~20mA(load : Max.500Ω)
Velocity (option) ±10V(output current : Max.5mA, load : Min.2kΩ)
or 4~20mA(load : Max.500Ω)
Alarm Open drain 50V 0.1A (for magnet missing)
Power supply +24(±2)VDC (70mA)
Sampling freq. Std 1kHz(total body length : up to 1250mm)
ENVIRONMENT
Operating temp. -20℃~+75℃
Storage temp. -40℃~+75℃
Vibration 15G(20~100Hz)
Shock 100G(2msec)
IP grade IP65
  • The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
  • The specification of stroke less than 300mm is equal that of stroke 300mm.

* Sampling frequency : Max. 3.75kHz (It depends on the total body length (shows in Model ⑧), and the consumption current increases.)