High-tech at every step

DURAVIS ESV 200-201 Series Steam Solenoid Valves

Model Pozisyon Bağlantı Ölçüsü (G) Orifis Ölçüsü Min Basınç
AC
(bar)
Max Basınç
AC
(bar)
Min Basınç
DC
(bar)
Max
Basınç DC
(bar)
Sızdırmazlık
ESV 200-02 N.K. 3/8" (DN10) 12 mm 0,35 5 0,35 5 PTFE
ESV 200-03 N.K. 1/2" (DN15) 15 mm 0,35 5 0,35 5 PTFE
ESV 200-04 N.K. 3/4" (DN20) 20 mm 0,35 5 0,35 5 PTFE
ESV 200-05 N.K. 1" (DN25) 25 mm 0,35 5 0,35 5 PTFE
ESV 200-06 N.K. 1 1/4" (DN32) 32 mm 0,5 3 0,5 3 EPDM
ESV 200-07 N.K. 1 1/2" (DN40) 40 mm 0,5 3 0,5 3 EPDM
ESV 200-08 N.K. 2" (DN50) 50 mm 0,5 3 0,5 3 EPDM
ESV 200-00-120 N.K. 1/8" (DN6) 12 mm 0,35 5 0,35 5 PTFE
ESV 200-01-120 N.K. 1/4" (DN8) 12 mm 0,35 5 0,35 5 PTFE
ESV 201-02 N.A. 3/8" (DN10) 12 mm 0,35 5 0,35 5 PTFE
ESV 201-03 N.A. 1/2" (DN15) 15 mm 0,35 5 0,35 5 PTFE
ESV 201-04 N.A. 3/4" (DN20) 20 mm 0,35 5 0,35 5 PTFE
ESV 201-05 N.A. 1" (DN25) 25 mm 0,35 5 0,35 5 PTFE
ESV 201-06 N.A. 1 1/4" (DN32) 32 mm 0,5 3 0,5 3 EPDM
ESV 201-07 N.A. 1 1/2" (DN40) 40 mm 0,5 3 0,5 3 EPDM
ESV 201-08 N.A. 2" (DN50) 50 mm 0,5 3 0,5 3 EPDM
ESV 201-00-120 N.A. 1/8" (DN6) 12 mm 0,35 5 0,35 5 PTFE
ESV 201-01-120 N.A. 1/4" (DN8) 12 mm 0,35 5 0,35 5 PTFE

General Information:
The Duravis ESV 200-201 series consists of 2/2-way servo-assisted solenoid valves designed primarily for the control of water, air, and neutral gases. These valves are widely used in industrial applications due to their quiet operation, long service life, and high flow capacity.

Technical Specifications:

  • Way Type: 2/2-way

  • Control Type: Servo-assisted (pilot operated)

  • Position: Normally Closed (N.C)

  • Body Material: Brass

  • Tube Material: Stainless Steel

  • Coil Voltages: 220/110/24 VAC or 24 VDC

  • Port Sizes: G1/2” – G1”

  • Pressure Range: 0.5 – 10 bar

  • Temperature Range: -10°C to +90°C

Applications:
Suitable for controlling air, water, neutral gases, and low-viscosity fluids. Commonly used in automation systems, industrial process lines, HVAC systems, and irrigation applications.

Mounting Position:
Can be mounted in any position, but vertical installation with the coil facing upward is recommended for best performance.