Santest GYDC-S1 Controller

High accuracy digital output (Parallel output)

GYDC-S1 outputs displacement of the magnet by a digital parallel output of minimum resolution 1μm. Using DIP switches in the case cover, you can change the code (binary or gray), the output direction, and the logic of the alarm output. And using pin A6 and A7 of parallel input in GYDC-S1, you can adjust zero and full points. With the captive software (GPM), zero and gain adjustment is possible at user side.

Specifications

Position(24bit) Parallel(NPN), Binary code (*1), Negative logic (*2)
Resolution STD 0.01mm (Min.0.001mm) (*3)
0.1mm(*4)
Alarm Open drain (*5)
Power supply ≦24VDC±5%(≦150mA)
Sampling freq. Std 1kHz(up to stroke 1000mm)
Temp. drift ≦±1μm/℃ (*6)
Operating temp. 0℃~+65℃
Storage temp. -20℃~+75℃

(*1) Can be changed to Gary code at user side
(*2) Tr On = output “0”
(*3) Associated probe : GYMR6, GYSE-R, GYcRS, GYMR5, GYFRS, GYKM-RS, GYKMR, GYRHP-MR6(*4) associated probe : GYMS, GYGS, GYPM, GYHR, GYHTR, GYcRP, GYKM, GYPMR, GYPE2K
(*5) Cable disconnection and magnet drop
(*6) Not include the temp. drift of the probe