GYSE-Q probe has the incremental output (A/B pulse), the resolution is Min.1μm (Quad divide). The working principle is based on a sampling detection method, in which pulse frequency is fixed to 250kHz or 500kHz (it depends on resolution). GYSE-Q doesn't output the pulse which continued like a linear encoder, so please be careful. The inside probe element can be detached from the outer housing, and with the captive software (GPM), zero and gain adjustment is possible at user side.
Specifications
| ACCURACY | ||||||
| Non-linearity | ≦±0.025%FS TYP | |||||
| Resolution | 0.1mm~0.001mm specified | |||||
| Repeatability | ≦±0.001%FS (Min. ±3μm) | |||||
| Temp. drift | ≦±15ppmFS/℃ | |||||
| OUTPUT | ||||||
| Position (STD) | A/B pulse, without Z pulse Line driver, pulse freq. 250kHz |
|||||
| Velocity(Option) | not available | |||||
| Alarm | Open drain 50V 0.1A (for lost magnet) | |||||
| Power supply | +24(±2)VDC(70mA) | |||||
| Sampling freq. | STD 1kHz(up to stroke 1000mm) | |||||
| ENVIRONMENT | ||||||
| Max. Pressure | 35MPa(probe rod) | |||||
| Operating temp. | -20℃~+75℃ | |||||
| Storage temp. | -40℃~+75℃ | |||||
| Vibration | 15G(20~100Hz) | |||||
| Shock | 100G(2msec) | |||||
| IP grade | IP67 |
- The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
- The specification of stroke less than 300mm is equal that of stroke 300mm.