Santest GYSE-A Probe
High Performance Analogue Output
(detachable probe element)
GYSE-A is a high performance analog output probe, and has the high resolution of 16bit. It has also velocity output. Using two pcs of magnet on the probe as another option, detecting each magnet position or relative distance between the two is possible. The inside probe element can be detached from the outer housing, and with the captive software (GPM), zero and gain adjustment is possible at user side. The sensor inside element flexible option is available and also most suitable for the exchange when space is small.
Specifications
| ACCURACY | ||||||
| Non-linearity | ≦±0.025%FS TYP | |||||
| Resolution | 16bit (1/65536) | |||||
| Repeatability | ≦±0.001%FS (Min. ±3μm) | |||||
| Temp. drift | ≦±20ppmFS/℃ | |||||
| OUTPUT | ||||||
| Position (STD) | 0~10V(output current : Max.5mA, load : Min.2kΩ) or 4~20mA(load : Max.500Ω) | |||||
| Velocity (Option) | ±10V(output current : Max.5mA, load : Min.2kΩ)or 4~20mA(load : Max.500Ω) | |||||
| Alarm | Open drain 50V 0.1A (for magnet missing) | |||||
| Power supply | +24(±2)VDC(70mA) | |||||
| Sampling freq. * | Std 1kHz (total rod length : up to 1250mm) | |||||
| ENVIRONMENT | ||||||
| Max. Pressure | 35MPa(probe rod) | |||||
| Operating temp. | -20℃~+75℃ | |||||
| Storage temp. | -40℃~+75℃ | |||||
| Vibration | 15G(20~100Hz) | |||||
| Shock | 100G(2msec) | |||||
| IP grade | IP67 |
- The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
- The specification of stroke less than 300mm is equal that of stroke 300mm.
* Sampling frequency : Max. 3.75kHz (It depends on the total rod length (shows in Model ⑨), and the consumption current increases.)