Santest GYHR Probe
High Performance – High Ambient Temperature
GYHR probe is designed to operate at high ambient temperatures up to 100°C, including sensor head. Electronic parts inside are minimized, yet provide high performance and reliability in the application. Cable used has reinforced silicon rubber sheath which stands ambient temperatures up to 150°C. Max cable extension is 100m.
Specifications
| ACCURACY | ||||||
| Non-linearity | ≦±0.1%FS TYP | |||||
| Resolution | (analogue)≦0.01%FS (digital)0.1mm | |||||
| Repeatability | ≦±0.05%FS | |||||
| Temp. drift | ≦±70ppmFS/°C | |||||
| ENVIRONMENT | ||||||
| Max. Pressure | 35MPa (probe rod) | |||||
| Operating temp. | -5℃~+100℃ | |||||
| Storage temp. | -40℃~+120℃ | |||||
| Vibration | 6G(40Hz 2mmPP) | |||||
| Shock | 50G(2msec) | |||||
| IP grade | IP64 (probe) |
-
Analogue output:GYHC(page 50-51Zero/Gain adjustment by trimmer of controller are possible, std within ±3%FS.
-
Digital output:GYDC-S1(page 54-55), GYDC-05(page 56-57)
- IRDS-GY(page 59) : When using the IRDM, you can connect with
CC-Link, CC-Link IE Field, PROFIBUS, EtherNet/IP, and EtherCAT. - DC-Q (page 58) : MELSEC-Q built-in unit