Santest GYHC Controller
High Accuracy Analogue Controller
GYHC controller outputs 0-10V or 4-20mA for position and ±10V (or 4-20mA) for velocity. Using digital process inside, fine resolution is possible (1/65536). With option, putting 2 pcs magnets on one probe and detecting each magnet position or relative distance between 2 magnets are possible. It has toggle switches on front face for zero/gain adjustment, mounting with DIN rail. With the captive software (GPM), zero and gain adjustment is possible at user side.
Specifications
| Resolution (position) | 16bit (1/65536) *1 ≦0.01%FS *2 |
| Position(OUT1) (OUT2:option) |
0-10V (Max.5mA, Min.2kΩ or 4-20mA (load:Max.500Ω) |
| Velocity(OUT2) (option) |
±10V or 4-20mA |
| Alarm *3 | Open collector 0.1A 30VDC *3 |
| Power supply | Std:+24VDC±5% (150mA) Option:+15VDC±5% (250mA) *4 |
| Sampling freq. | Std 1kHz (up to stroke 1000mm) |
| Temp. drift | ≦±10ppmFS/°C |
| Operating temp. | 0°C-+65°C |
| Storage temp. | -20°C-+85°C |