Cumhuriyetimizin 100. Yılı Kutlu Olsun
High-tech at every step

Santest GYFC2 / GYFC3 Analog Controller

Analogue Output

GYFC2/3 controller outputs 0-10V or 4-20mA for position and ±10V for velocity (velocity output : option). Having alarm output for cable cut and missing magnet (standard function). GYFC2/3 controller can be used in combination with GYMR6, GYcRP, GYcRS, GYMR5, GYFRS, and GYKM-RS probe. GYFC2/3 controller can’t be used in combination with GYSE-R probe. And a connection with a probe will be a terminal stand, not a connector for GYFC3.

Specifications

Resolution (position) ≦0.005%FS *1
≦0.01%FS *2
Position (OUT1)
(OUT2: option)
0~10V(Max.5mA, Min.2kΩ)
4~20mA(load:Max.500Ω)
or inverted output etc
Velocity (option) ±10V(Resolution:1%FS)
Alarm *3 Contact 1A 30VDC *3
Power supply Std:+24VDC±5%(≦350mA)
Option:±15VDC, +12VDC *4
Sampling freq. Std 1kHz (up to stroke 1000mm)
Temp. drift ≦±20ppmFS/℃
Operating temp. 0℃~+65℃
Storage temp. -20℃~+85℃