Santest GYFC2 / GYFC3 Analog Controller
Analogue Output
GYFC2/3 controller outputs 0-10V or 4-20mA for position and ±10V for velocity (velocity output : option). Having alarm output for cable cut and missing magnet (standard function). GYFC2/3 controller can be used in combination with GYMR6, GYcRP, GYcRS, GYMR5, GYFRS, and GYKM-RS probe. GYFC2/3 controller can’t be used in combination with GYSE-R probe. And a connection with a probe will be a terminal stand, not a connector for GYFC3.
Specifications
| Resolution (position) | ≦0.005%FS *1 ≦0.01%FS *2 |
| Position (OUT1) (OUT2: option) |
0~10V(Max.5mA, Min.2kΩ) 4~20mA(load:Max.500Ω) or inverted output etc |
| Velocity (option) | ±10V(Resolution:1%FS) |
| Alarm *3 | Contact 1A 30VDC *3 |
| Power supply | Std:+24VDC±5%(≦350mA) Option:±15VDC, +12VDC *4 |
| Sampling freq. | Std 1kHz (up to stroke 1000mm) |
| Temp. drift | ≦±20ppmFS/℃ |
| Operating temp. | 0℃~+65℃ |
| Storage temp. | -20℃~+85℃ |