Santest GYDC-05 Controller
High accuracy digital output (Parallel, SSI, A/B pulse)
GYDC-05 controller enables digital output of 1μm resolution and also analogue output of the position or the velocity (option). With option, SSI output and the incremental output (A/B pulse) are available. And putting 2 pcs magnets on one probe and detecting each magnet position or relative distance between 2 magnets are possible. It has toggle switches on front face for zero/gain adjustment, mounting with DIN rail. With the captive software (GPM), zero and gain adjustment is possible at user side.
Specifications
| Position (digital)(24bit) |
Parallel, Binary code *1 , negative logic *2 (option:SSI or A/B incremental output) |
| Resolution (digital) |
STD 0.01mm(Min. 0.001mm) *3 0.1mm *4 |
| Position(OUT1) (analogue) |
0~10V(Max.5mA, Min.2kΩ) or 4~20mA(load:Max.500Ω) |
| Resolution (analogue) |
16bit(1/65536)*3 ≦0.01%FS *4 |
| Velocity (OUT2) |
Option ±10V or 4~20mA |
| Alarm *2 | Open collector 0.1A 30VDC *2 |
| Power supply | +24VDC±5%(≦160mA) |
| Sampling freq. *6 | Std 1kHz(up to stroke 1000mm) |
| Temp. drift | ≦±10ppmFS/℃ |
| Operating temp. | 0℃~+65℃ |
| Storage temp. | -20℃~+75℃ |
(*1) Can be changed to Gary code at user side
(*2) Tr On = output “0”
(*3) Associated probe : GYMR6, GYSE-R, GYcRS, GYMR5, GYFRS, GYKM-RS, GYKMR, GYRHP-MR6
(*4) Associated probe : GYMS, GYGS, GYPM, GYHR, GYHTR, GYcRP, GYKM, GYPMR, GYPE2K
(*5) Cable disconnection and magnet drop
(*6) Sampling frequency : Max. 3.75kHz (It depends on the probe stroke.)