General Description
Immersion Type Flowmeters are designed for DN15...DN600 pipes, are easy to install, have no pressure loss, yet are very affordable. It can be used easily in chemical fluids. Our product provides 4-20 mA, pulse and 2 relay outputs as standard. Our standard product with CPVC body can also be produced as PVDF, Brass, AISI316 depending on the process. You can easily monitor the instantaneous and total flow and output signal level with the large LCD display on it. It can be easily used in water, wastewater, pools, osmosis systems and chemical applications.
Technicial Specifications
Measuring Range-Liquid0.15...8 m/sec.
Connection Size1 1/4"
Wet PartsCPVC,PVDF,Brass or AISI316
Temperature -20...120°C
Pressure10 Bar max. 25 Bar (Opt.)
Sensitivity<±0.75% T.S.
ProtectionIP65
Supply12...24V DC
Output 4-20 mA, Pulse and 2 Relays
Applied Pipe DiametersDN15...DN600
Instant and Total Display on LCD
ApplicationWater and Chemical Liquids
Features
Durable and Lightweight Design
High Sensitivity
Long lasting
Resistant to Chemical Fluids
Large Measuring Capability 53:1
Large LCD Screen