GENERAL FEATURES
Thermowells are protective cases made of solid or pipe material into which thermocouples, resistance thermometers and other temperature sensors are placed. It is especially widely used in processes where pressure, viscosity, fluid speed, chemical and mechanical abrasives are effective. Thermoweller, selected appropriately according to the operating conditions, prevents damage to the temperature sensors and ensures longer life due to the above features.
In case of failure of temperature sensors, the sensor mounted inside the Thermowell is easily removed and replaced.
In this way, the process environment and system are not interfered with. If the Thermoweller, which is made of material suitable for environmental conditions, is selected by taking the process conditions into consideration, the temperature measurement system will have a long life.
ELIMKO THERMOWELL TYPES
Elimko Thermowell codes according to their applications;
TW/T : Screw Connection Type
TW/W: Welded Socket Type
TW/V : Vanstone Flanged Type
TW/F : Flanged Type
TW/WI : Welded Type
SAMPLE CODING
TW/FS-B18-P-M-FsM02-FrM04-THR-Fwt00-IC01-H110-P01-U120-L00-A130-Q02-V02-Tth02-Wm18-Fm18- O01-O02-O03
Well Type (TW) = TW/FS Flanged Type Straight Thermowell,
Hole Diameter (B) = 18 mm, Manufacturing Method (P) = Pipe, Manufacturing Standard (M) = Metric,
Flange Pipe Dimension (FsM02) = DN40, Flange Pressure Class (FrM04) = PN100,
Flange Type (THR) = Flange with threaded inlet, Flange welding Type (Fwt00) = Non-welded,
Element Well Connection (IC01) = M20X1.5, Well Head Length (H02) = 110 mm,
Well Head Diameter (P01) = 30 mm, Plunge Length (L) = 1200, Tip Length (L00) = Without tip,
Element Length (A) = 1300, Body / Bottom Dimension (Q02) = 22 mm, Tip Diameter (V02) = 22 mm,
Tip Thickness (Tth02) = 10 mm, Well Material (Wm18) = Teflon, Flange Material (Fm18) = Teflon,
Option (001) = Plug and Chain / (002) = Writing Tag No on Stainless Steel Plate / (003) = Pressure Test